For the complete documentation index, see llms.txt. This page is also available as Markdown.

Error Codes

This reference documents error and fault codes for all device types in KEMPER Connect.

Error Code Overview

Devices report error status via dedicated fields:

Device Type
Error Field
Warning Field

AirDome

FEHLERCODE

WARNING

Clean Air Tower (Self-Cleaning)

FEHLERCODE

-

Clean Air Tower (Disposable)

FAULT_CODE

-

VacuFil 125

fault_code

-

A value of 0 indicates no error (system healthy).

AirDome Error Codes

Errors (FEHLERCODE)

Code
Name
Description
Action

0

OK

No error

None required

F90

Frequency inverter error

Inverter malfunction

Check power, contact service

F94

Critical filter pressure

Filter pressure too high

Check filter, may need replacement

F95

Control error

System control issue

Restart, contact support if persists

F96

Compressed air not connected

No air supply

Connect compressed air supply

Warnings (WARNING)

Code
Name
Description
Action

0

OK

No warning

None required

SER

Maintenance overdue

Service interval exceeded

Schedule maintenance

A03

Filter pressure too high

Elevated filter pressure

Monitor, schedule service

A04

No flow rate calculation

Cannot calculate flow

Check sensors, contact support

Clean Air Tower (Self-Cleaning) Error Codes

Errors (FEHLERCODE)

Code
Name
Description
Action

0

OK

No error

None required

E00

Frequency inverter error

Inverter malfunction

Check power, contact service

E03

Compressed air not connected

No air supply

Connect compressed air

E05

Control error

System control issue

Restart, contact support

Clean Air Tower (Disposable) Fault Codes

Faults (FAULT_CODE)

Code
Name
Description
Action

0

OK

No fault

None required

E02

Airflow control error

Fan/airflow issue

Check fan, verify no obstructions

E03

Maintenance required

Service needed

Schedule maintenance

E04

Motor temperature too high

Overheating

Allow cooling, check ventilation

E07

Modbus error

Communication failure

Check connections, restart

E12

Airflow too low

Insufficient airflow

Check for blockages, filter clogged

VacuFil 125 Fault Codes

Faults (fault_code)

Code
Name
Description
Action

0

OK

No fault

None required

Additional codes may be device-specific. Consult device documentation.

Error Severity

Critical Errors

Require immediate attention:

  • F90/E00: Frequency inverter

  • F94: Critical pressure

  • E04: Motor overheating

Warning Errors

Monitor and plan service:

  • SER: Maintenance overdue

  • A03: Elevated pressure

  • E03: Maintenance required

Communication Errors

May resolve on retry:

  • E07: Modbus error

  • A04: Calculation failure

Error Display in UI

Settings Tab

Each device's Settings tab shows:

  • Current error/fault code

  • Status message

  • "System Healthy" or error description

Dashboard

When error detected:

  • "Service Required" alert

  • Red status badge

  • Error details available in Settings

Assets List

Device cards show:

  • Error badge on affected devices

  • Quick visual identification

Common Troubleshooting

Compressed Air Errors (F96, E03)

1

Verify air supply is connected

Ensure compressed air lines are connected to the device.

2

Check pressure is adequate

Typical required pressure: 6-8 bar. Verify actual pressure meets requirements.

3

Inspect air lines for leaks

Look for visible damage or audible leaks and repair as needed.

4

Ensure filter cleaning system functional

Confirm the filter cleaning/maintenance system is operating correctly.

Motor/Inverter Errors (F90, E00)

1

Check power supply stable

Verify voltage and supply stability to the device.

2

Verify no overload condition

Confirm the device isn't overloaded or operating beyond rated capacity.

3

Inspect electrical connections

Check wiring and connectors for looseness or damage.

4

Contact service for persistent issues

If the error persists after checks, contact KEMPER service.

Temperature Errors (E04)

1

Allow motor to cool down

Stop operation to let the motor reach safe temperature.

2

Reduce continuous operation time

Limit long continuous runs to avoid overheating.

3

Check ventilation around motor

Ensure adequate airflow and no obstructions to ventilation.

4

Reduce boost mode usage

Minimize use of high-power/boost modes that increase heat.

5

Contact service if recurring

If overheating returns, contact KEMPER service.

Airflow Errors (E02, E12)

1

Check for physical obstructions

Inspect ducts, intakes, and outlets for blockages.

2

Inspect filter condition

Look for clogged or damaged filters; replace if necessary.

3

Verify fan operation

Confirm the fan runs and operates at expected speed.

4

Replace filter if clogged

If cleaning doesn't restore flow, install a new filter.

Communication Errors (E07)

1

Check cable connections

Ensure communication cables are connected and undamaged.

2

Verify device powered properly

Confirm the device has stable power and is turned on.

3

Restart device

Power-cycle the device to attempt to clear transient communication faults.

4

Contact support if persists

If communication doesn't recover, contact KEMPER support.

Service Contact

For unresolved errors:

  • Contact KEMPER service

  • Provide error code and device serial