# Error Codes

This reference documents error and fault codes for all device types in KEMPER Connect.

## Error Code Overview

Devices report error status via dedicated fields:

| Device Type                     | Error Field | Warning Field |
| ------------------------------- | ----------- | ------------- |
| AirDome                         | FEHLERCODE  | WARNING       |
| Clean Air Tower (Self-Cleaning) | FEHLERCODE  | -             |
| Clean Air Tower (Disposable)    | FAULT\_CODE | -             |
| VacuFil 125                     | fault\_code | -             |

A value of **0** indicates no error (system healthy).

## AirDome Error Codes

### Errors (FEHLERCODE)

| Code | Name                         | Description              | Action                               |
| ---- | ---------------------------- | ------------------------ | ------------------------------------ |
| 0    | OK                           | No error                 | None required                        |
| F90  | Frequency inverter error     | Inverter malfunction     | Check power, contact service         |
| F94  | Critical filter pressure     | Filter pressure too high | Check filter, may need replacement   |
| F95  | Control error                | System control issue     | Restart, contact support if persists |
| F96  | Compressed air not connected | No air supply            | Connect compressed air supply        |

### Warnings (WARNING)

| Code | Name                     | Description               | Action                         |
| ---- | ------------------------ | ------------------------- | ------------------------------ |
| 0    | OK                       | No warning                | None required                  |
| SER  | Maintenance overdue      | Service interval exceeded | Schedule maintenance           |
| A03  | Filter pressure too high | Elevated filter pressure  | Monitor, schedule service      |
| A04  | No flow rate calculation | Cannot calculate flow     | Check sensors, contact support |

## Clean Air Tower (Self-Cleaning) Error Codes

### Errors (FEHLERCODE)

| Code | Name                         | Description          | Action                       |
| ---- | ---------------------------- | -------------------- | ---------------------------- |
| 0    | OK                           | No error             | None required                |
| E00  | Frequency inverter error     | Inverter malfunction | Check power, contact service |
| E03  | Compressed air not connected | No air supply        | Connect compressed air       |
| E05  | Control error                | System control issue | Restart, contact support     |

## Clean Air Tower (Disposable) Fault Codes

### Faults (FAULT\_CODE)

| Code | Name                       | Description           | Action                              |
| ---- | -------------------------- | --------------------- | ----------------------------------- |
| 0    | OK                         | No fault              | None required                       |
| E02  | Airflow control error      | Fan/airflow issue     | Check fan, verify no obstructions   |
| E03  | Maintenance required       | Service needed        | Schedule maintenance                |
| E04  | Motor temperature too high | Overheating           | Allow cooling, check ventilation    |
| E07  | Modbus error               | Communication failure | Check connections, restart          |
| E12  | Airflow too low            | Insufficient airflow  | Check for blockages, filter clogged |

## VacuFil 125 Fault Codes

### Faults (fault\_code)

| Code | Name | Description | Action        |
| ---- | ---- | ----------- | ------------- |
| 0    | OK   | No fault    | None required |

Additional codes may be device-specific. Consult device documentation.

## Error Severity

### Critical Errors

Require immediate attention:

* F90/E00: Frequency inverter
* F94: Critical pressure
* E04: Motor overheating

### Warning Errors

Monitor and plan service:

* SER: Maintenance overdue
* A03: Elevated pressure
* E03: Maintenance required

### Communication Errors

May resolve on retry:

* E07: Modbus error
* A04: Calculation failure

## Error Display in UI

### Settings Tab

Each device's Settings tab shows:

* Current error/fault code
* Status message
* "System Healthy" or error description

### Dashboard

When error detected:

* "Service Required" alert
* Red status badge
* Error details available in Settings

### Assets List

Device cards show:

* Error badge on affected devices
* Quick visual identification

## Common Troubleshooting

### Compressed Air Errors (F96, E03)

{% stepper %}
{% step %}

### Verify air supply is connected

Ensure compressed air lines are connected to the device.
{% endstep %}

{% step %}

### Check pressure is adequate

Typical required pressure: 6-8 bar. Verify actual pressure meets requirements.
{% endstep %}

{% step %}

### Inspect air lines for leaks

Look for visible damage or audible leaks and repair as needed.
{% endstep %}

{% step %}

### Ensure filter cleaning system functional

Confirm the filter cleaning/maintenance system is operating correctly.
{% endstep %}
{% endstepper %}

### Motor/Inverter Errors (F90, E00)

{% stepper %}
{% step %}

### Check power supply stable

Verify voltage and supply stability to the device.
{% endstep %}

{% step %}

### Verify no overload condition

Confirm the device isn't overloaded or operating beyond rated capacity.
{% endstep %}

{% step %}

### Inspect electrical connections

Check wiring and connectors for looseness or damage.
{% endstep %}

{% step %}

### Contact service for persistent issues

If the error persists after checks, contact KEMPER service.
{% endstep %}
{% endstepper %}

### Temperature Errors (E04)

{% stepper %}
{% step %}

### Allow motor to cool down

Stop operation to let the motor reach safe temperature.
{% endstep %}

{% step %}

### Reduce continuous operation time

Limit long continuous runs to avoid overheating.
{% endstep %}

{% step %}

### Check ventilation around motor

Ensure adequate airflow and no obstructions to ventilation.
{% endstep %}

{% step %}

### Reduce boost mode usage

Minimize use of high-power/boost modes that increase heat.
{% endstep %}

{% step %}

### Contact service if recurring

If overheating returns, contact KEMPER service.
{% endstep %}
{% endstepper %}

### Airflow Errors (E02, E12)

{% stepper %}
{% step %}

### Check for physical obstructions

Inspect ducts, intakes, and outlets for blockages.
{% endstep %}

{% step %}

### Inspect filter condition

Look for clogged or damaged filters; replace if necessary.
{% endstep %}

{% step %}

### Verify fan operation

Confirm the fan runs and operates at expected speed.
{% endstep %}

{% step %}

### Replace filter if clogged

If cleaning doesn't restore flow, install a new filter.
{% endstep %}
{% endstepper %}

### Communication Errors (E07)

{% stepper %}
{% step %}

### Check cable connections

Ensure communication cables are connected and undamaged.
{% endstep %}

{% step %}

### Verify device powered properly

Confirm the device has stable power and is turned on.
{% endstep %}

{% step %}

### Restart device

Power-cycle the device to attempt to clear transient communication faults.
{% endstep %}

{% step %}

### Contact support if persists

If communication doesn't recover, contact KEMPER support.
{% endstep %}
{% endstepper %}

## Service Contact

For unresolved errors:

* Contact KEMPER service
* Provide error code and device serial
* Describe symptoms and troubleshooting attempted

## Related Documentation

* [AirDome Settings](file:///6726661/asset-types/airdome/settings.md)
* [Clean Air Tower (Self-Cleaning) Settings](file:///6726661/asset-types/clean-air-tower-abreinigbar/settings.md)
* [Clean Air Tower (Disposable) Settings](file:///6726661/asset-types/clean-air-tower-einweg/settings.md)
* [VacuFil 125 Settings](file:///6726661/asset-types/vacufil-125/settings.md)
* [Service Monitoring](file:///6726661/monitoring/service/overview.md)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation dynamically by asking a question.

Perform an HTTP GET request on the current page URL with the `ask` query parameter, and the optional `goal` query parameter:

```
GET https://docs.kemperconnect.de/reference/error-codes.md?ask=<question>&goal=<endgoal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is optional and describes the broader end goal you are ultimately trying to accomplish on behalf of the user. GitBook uses it to tailor the answer towards what is most useful for that goal.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.